Cable Group
Construction
Attenuation @ 1000 MHz
0.85 dB/m
Impedance
50 Ω
Inner Conductor
Silver Plated Copper Clad Steel (SCCS)
Dielectric Material
Outer Conductor
Silver Plated Copper Braid
Jacket Material
Typical Electrical Specifications | Typical Mechanical Specifications | ||
---|---|---|---|
Operating frequency range | DC to 3 GHz | Inner conductor (mm) | 7 x 0.175 |
Capacitance (pF/m) | 96.45 | Dielectric (mm) | 1.52 |
Velocity of propagation (%) | 70 | Outer conductor (mm) | 1.95 |
Shielding effectiveness (dB) | >40 | Jacket (mm) | 2.50 |
Maximum operating voltage (KVrms) | 1.2 | Operating temperature | -55 to +200 °C |